Roof Filter Fans 
                        F2E Cabinet Top Ventilation
Interior
 The precondition to use the top fan is that the ambient termperature should be  lower than the temperature required in the cabinet.
Function 
 The high-power centrifugal top fan can vent the high heat load by the greatest degree. The centrifugal fan not only can avoid the vortex vented by the general shield magnetic fan, but also can reduce the noise caused by the friction of air. The FK series of Exit Filter can be used in the inlet in order to prevent from entering the humidity and dust.
Design
 The centrifugal top fan is  larruping. It is handsome and it has the good function and reasonable structure. It also doesn't take up the interior space. It can well satisfy requirement of the present market with its unique design.    The centrifugal top fan is  larruping. It is handsome and it has the good function and reasonable structure. It also doesn't take up the interior space. It can well satisfy requirement of the present market with its unique design.
	
		
			
				Exhauster on the top    Type
			
			
				F2E190-230-DP
			
			
				F2E220-230-DP
			
			
				F2E225-230-DP
			
		
		
			
				Voltage Frequency
			
			
				230V 50/60HZ
			
			
				230V 50/60HZ
			
			
				230V 50/60HZ
			
		
		
			
				Air Flow, Ventilation Freely
			
			
				570/620m3/h
			
			
				860/900m3/h
			
			
				1200/1340m3/h
			
		
		
			
				Flux of air equip filter exported Include filtering pad of standard
			
			
				1×FK6626.300
456/496m3/h
			
			
				1×FK6626.300
688/540m3/h
			
			
				1×FK6626.300
960/1072m3/h
			
		
		
			
				Axle flow blower
			
			
				Capacitance electromotion
			
			
				Capacitance electromotion
			
			
				Capacitance electromotion
			
		
		
			
				Rated Current
			
			
				0.26A/0.34A
			
			
				0.38A/0.40A
			
			
				0.60A/0.88A
			
		
		
			
				Power
			
			
				58/75W
			
			
				85/90W
			
			
				135/200W
			
		
		
			
				Noise Level
			
			
				62/64dBA
			
			
				73/74dBA
			
			
				69/71dBA
			
		
		
			
				Temperature Range
			
			
				'-10℃~55℃
			
			
				'-10℃~55℃
			
			
				'-10℃~60℃
			
		
		
			
				The quantity and size of the wind inlet filter can be decided according to the concrete requirement.
			
			
				
			
			
				
			
			
				
			
		
	
	
		
			
				Type
			
			
				A/B
			
			
				C
			
			
				D/E
			
			
				F/G
			
			
				H/I
			
			
				J
			
			
				ΦK
			
			
				Φ1
			
			
				Φ2
			
			
				L
			
		
	
	
		
			
				F2E190-230-DP
			
			
				270
			
			
				130
			
			
				267
			
			
				310
			
			
				226.8
			
			
				98.4
			
			
				195
			
			
				7.8
			
			
				15
			
			
				97
			
		
		
			
				F2E220-230-DP
			
			
				270
			
			
				130
			
			
				267
			
			
				310
			
			
				226.8
			
			
				98.4
			
			
				195
			
			
				7.8
			
			
				15
			
			
				97
			
		
		
			
				F2E225-230-DP
			
			
				270
			
			
				130
			
			
				267
			
			
				310
			
			
				226.8
			
			
				98.4
			
			
				195
			
			
				7.8
			
			
				15
			
			
				97